All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

In physical rehabilitation, is diffused the skin irradiation with near infrared laser at a fluence below 140 J/cm', achieving a bio-stimulating effect that is due to the absorption of radiation in mitochondria rather than the simple heating of tissues. In order to deliver radiation without thermal damage of the skin, are used radiation pulses which duration does not allow heat accumulation and propagation far from the irradiated target; this requires laser sources with average power below 10 W implying a safety classification as "potentially dangerous for eye and skin", or "class 4" according to the applicable international standards. In this paper, 6 laser therapy devices, of 5 different manufactures and models have been analyzed from the point of view of actual radiation output and user safety. In each case, one or more of the characteristic declared by the manufacturer in the user manual have been found different from the actual measured value. The actual accessible energy levels have been found to be complying with risk class 3B. The impact of the new version of the Standard IEC 60825-1 (2014), is also discussed, considering in particular the possible classification in the new class IC, and the maximum permissible levels for pulsed lasers. An extension of the measurement protocols is proposed in order to assure effective and safe use of laser in physical therapy.

Altmetrics

Downloads

Download data is not yet available.

Citations

1) Hamblin MR, Demidova T. Mechanisms of low level light therapy, SPIE Digital Library, vol. 6140, 2006. DOI: https://doi.org/10.1117/12.646310
2) Sommer PA, Pinheiro A, Mester RP, Franke HT, Whelan. Biostimulatory Windows in Low-Intensity Laser Activation: Lasers, Scanners, and NASA's Light-Emitting Diode Array System. Journal of Clinical Laser Medicine & Surgery, vol. 9, num. 1, 2001, pag. 29-33. 3) Cotler HB, Chow RT, Hamblin MR, Carroll J. The Use of Low Level Laser Therapy (LLLT) For Musculoskeletal Pain. MOJ Orthop Rheumatol. 2015;2(5). pii: 00068. Epub 2015 Jun 9. DOI: https://doi.org/10.1089/104454701750066910
4) Spitler R, Berns MW. Comparison of laser and diode sources for acceleration of in vitro wound healing by low-level light therapy. J Biomed Opt. 2014 Mar 1;19(3):38001. doi: 10.1117/1.JBO.19.3.038001. DOI: https://doi.org/10.1117/1.JBO.19.3.038001
5) Lubart R, Friedmann H, Lavie R. Photobiostimulation as a function of different wavelengths. Laser Therapy, vol. 12, 2000, pag. 38-41. DOI: https://doi.org/10.5978/islsm.12.38
6) Karu. Mitochondrial Signaling in Mammalian Cells Activated by Red and Near-IR Radiation. Photochemistry and Photobiology, vol. 84, num. 5, 2008, pag. 1091-1099. DOI: https://doi.org/10.1111/j.1751-1097.2008.00394.x
7) Pinto EC, Leal Junior RA, Lopes-Martins B, Vanin AA, Baroni BM, Grosselli D, De Marchi T, Iversen VV, Bjordal JM. Effect of 830 nm low-level laser therapy in exercise-induced skeletal muscle fatigue in humans. Lasers in Medical Science, vol. 24, num. 3, 2009, pag. 425-431. DOI: https://doi.org/10.1007/s10103-008-0592-9
8) Lanzafame RJ, Stadler I, Coleman J, Haerum B, Oskoui P, Whittaker M, Zhang R. Temperature-Controlled 830-nm Low-Level Laser Therapy of Experimental Pressure Ulcers. Photomedicine and Laser Surgery, vol. 22, num. 6, 2004, pag. 483-488. DOI: https://doi.org/10.1089/pho.2004.22.483
9) Svelto O. Principles of lasers. 5th edition Springer Verlag 2010. 10) Niemz MK, Laser-Tissue interaction, Springer, Berlin, 1996, p. 42. 11) Sabino CP, Meneguzzo DT, Benetti E, Kato IT, Prates R, Riberio M. Red laser attenuation in biological tissues: study of the inflammatory process and pigmentation influence. SPIE Digital Library, 2012. 12) IEC 60825-1:2014 "Safety of laser products Part 1 Equipment classification, requirements and user's guide"
13) IEC 60601-2-22:2007 "Medical electric equipment, Part 2: Particular requirements for the safety of diagnostic and therapeutic laser equipment".
14) Schulmeister K. Impact of the New Editions of TEC 60825-1 and ANSI Z136.1 on Permitted Exposure and Emission of Products. paper presented at ILSC International Laser Safety Conference, march 2013.
15) Technical Application Note TAN2008006 Quantum Efficiency Curve Comparison for ICX445, Revised July 16, 2010, Point Grey Research Inc 2051 Riverside Way Richmond, BC, Canada V6W 1K7 - www.ptgrey.com 16) Reference Document revision 1.0 PS-0048 Image sensor color correction Truesense Imaging, Inc. 1964 Lake Avenue Rochester, NY 14615 - www.truesenseimaging.com 17) Paschotta R. Encyclopedia of Laser Physics and Technology. WileyVCH, Berlin, 2008.

How to Cite



Control measurements for lasers in physiotherapy: [Misure di controllo per i laser in fisioterapia]. (2025). Giornale Italiano Di Medicina Del Lavoro Ed Ergonomia, 39(1), 56-63. https://doi.org/10.4081/gimle.605