Original Articles
4 March 2025
Vol. 39 No. 4 (2017)

Validity and reliability of textile system Sensoria for posturographic measurements

[Validità e affidabilità del sistema tessile Sensoria per le misurazioni post-urografiche]

Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
20
Views
15
Downloads

Authors

ABSTRACT. Smart fabrics and interactive textiles are a relatively new area of research, with many potential applications in the field of biomedical engineering. The ability of smart textiles to interact with the body provides a novel means to sense the wearer's physiology and respond to the needs of the wearer. Physiological signals, such as heart rate, breathing rates, and activity levels, are useful indicators of health status. These signals can be measured by means of textile-based sensors integrated into smart clothing which has the ability to keep a digital record of the patient's physiological responses since his or her last clinical visit, allowing doctors to make a more accurate diagnosis. Similarly, in rehabilitation, it is difficult for therapists to ensure that patients are complying with prescribed exercises. Smart garments sensing body movements have the potential to guide wearers through their exercises, while also recording their individual movements and adherence to their prescribed programme.
In this paper, we present the new wireless textile system Sensoria, with pressure sensing capability for static posturography. The gold standard for static posturography is currently the use of a pressure or force plate but, due to their very complexity and expensiveness, the applicability outside laboratories is extremely limited. This paper focuses on the agreement between the static computed posturography assessed by means of a traditional stabilometric platform and the Sensoria system, in twenty subjects with Parkinson's Disease (PD). Preliminary results showed a significant agreement between the two methods, suggesting a clinical use of Sensoria for low cost home care based balance impairment assessments.

Altmetrics

Downloads

Download data is not yet available.

Citations

1) Alemdar H, Ersoy C. Wireless Sensor Networks for Healthcare: A Survey. Computer Networks. 2010; Vol.54, pp.2688-2710 DOI: https://doi.org/10.1016/j.comnet.2010.05.003
2) Paradiso R, Loriga G, and Taccini N. Wearable System for Vital Signs Monitoring. In Wearable eHealth Systems for Personalised Health Management: State of the Art and Future Challenges, vol. 108, Studies in Health Technology and Informatics, A. Lymberis and D. de Rossi, Eds. Nieuwe Hemweg 6B, 1013 BG Amsterdam: IOS Press, 2004, pp. 253-259.
3) Taccini N, Loriga G, Dittmar A, et al. Knitted Bioclothes for Health Monitoring. In Proceedings of the 26th Annual International Conference of the IEEE EMBS, San Francisco, CA, 2004, pp. 2165-2168. DOI: https://doi.org/10.1109/IEMBS.2004.1403633
4) Linti C, Horter H, Osterreicher P, et al. Sensory baby vest for the monitoring of infants. In Proceedings of the International Workshop on Wearable and Implantable Body Sensor Networks (BSN 2006), 2006, pp. 135-137. DOI: https://doi.org/10.1109/BSN.2006.49
5) Park S, Jayaraman S. e-Health and Quality of Life: The Role of the Wearable Motherboard. In Wearable eHealth Systems for Personalised Health Management: State of the Art and Future Challenges, vol. 108, Studies in Health Technology and Informatics.
6) Patel S, Park H, Bonato, P, et al. A review of wearable sensors and systems with application in rehabilitation, Journal of Neuro Engineering and Rehabilitation. 2012; 9:21. DOI: https://doi.org/10.1186/1743-0003-9-21
7) Vieira TMM, Oliveira LF, Nadal J. An overview of agerelated changes in postural control during quiet standing tasks using classical and modern stabilometric descriptors. J Electromyogr Kinesiol. 2009. DOI: https://doi.org/10.1016/j.jelekin.2008.10.007
8) Winter, David A. Anatomy, Biomechanics, Control of Balance during Standing and Walking. 1995; ISBN: 0-9699420-0-1.
9) luppariello L, D'Addio G, Pagano G, et al. Effects of wavelets analysis on power spectral distributions in posturographic signal processing. TEEE International Symposium on Medical Measurements and Applications, MeMeA 2016 - Proceedings, art. no. 7533718. DOI: https://doi.org/10.1109/MeMeA.2016.7533718
10) luppariello L, Bifulco P, D'Addio G, et al. The effects of the vibratory stimulation of the neck muscles for the evaluation of stepping performance in Parkinson's Disease. Medical Measurements and Applications (MeMeA). IEEE International Symposium on, vol., no., pp.606-609, 7-9 May 2015. DOI: https://doi.org/10.1109/MeMeA.2015.7145275
11) Cesarelli M, luppariello L, Romano M, et al. Bioengineering activities in proprioceptive and robotic rehabilitation at Salvatore Maugeri Foundation. AEIT International Annual Conference, AEIT 2015; art. no. 7415277. DOI: https://doi.org/10.1109/AEIT.2015.7415277
12) Goldie PA, Bach TM, Evans OM. Force platform measures for evaluating postural control: reliability and validity Arch Phys Med Rehabil. 1989; 70 (7), pp. 510-517.
13) Middleton J, Sinclair P, Patton R. Accuracy of centre of pressure measurement using a piezoelectric force platform Clin Biomech. 1999; 14 (5): pp. 357-360. DOI: https://doi.org/10.1016/S0268-0033(98)00079-5
14) Rogind H, Simonsen H, Era P, Bliddal H. Comparison of Kistler a force platform and Chattec Balance System for measurement of postural sway: correlation and test-retest reliability Scand J Med Sci Sports. 2006; (2): pp. 106-114. DOI: https://doi.org/10.1034/j.1600-0838.2003.01139.x
15) D'Addio G, Iuppariello L, Pagano G, et al. New posturographic assessment by means of novel e-textile and wireless socks device. TEEE International Symposium on Medical Measurements and Applications, MeMeA. 2016; Proceedings, art. no. 7533798. DOI: https://doi.org/10.1109/MeMeA.2016.7533798
16) Hurkmans HLP, Bussmann JBJ, Benda E, et al. Techniques for measuring weight bearing during standing and walking Clin Biomech. 2003; 18: pp. 576-589. DOI: https://doi.org/10.1016/S0268-0033(03)00116-5
17) Arpaia P, Cimmino P, De Matteis E, et al. A low-cost force sensorbased posturographic plate for home care telerehabilitation exergaming. Measurement. 2014; vol 51 (1): pp. 400-410. DOI: https://doi.org/10.1016/j.measurement.2014.01.031
18) Arpaia P, Cimmino P, De Matteis E, et al. A balance board device for home care telerehabilitation exergaming. 20th IMEKO World Congress. 2012; 2, pp. 1459-1462.
19) Sensoria (®) is a registered trademark of Sensoria Inc, Redmond, WA, USA. http://www.sensoriafitness.com.
20) Schilling RJ, Bollt EM, Fulk GD, Skufca JD, et al. A quiet standing index for testing the postural sway of healthy and diabetic adults across a range of ages. Biomedical Engineering, IEEE. 2009; vol. 56, no. 2, pp. 292-302. DOI: https://doi.org/10.1109/TBME.2008.2003270
21) Iuppariello L, Bifulco P, Romano M, et al. Submovements composition and quality assessment of reaching movements in subjects with Parkinson's Disease. IEEE International Symposium on Medical Measurements and Applications, MeMeA. 2015; Proceedings, art. no. 7145222, pp. 329-334. DOI: https://doi.org/10.1109/MeMeA.2015.7145222
22) Rocchi L, Chiari A, Cappello A. Identification of distinct characteristics of postural sway in Parkinson's disease: a feature selection procedure based on principal component analysis. Neurosci Lett 2006; 394(2):140-145. DOI: https://doi.org/10.1016/j.neulet.2005.10.020
23) D'Addio G, Gallo F, Iuppariello L, et al. Comparison between clinical and instrumental assessing using Wii Fit system on balance control. In Medical Measurements and Applications (MeMeA), IEEE International Symposium on. 2014; pp. 1-5 DOI: https://doi.org/10.1109/MeMeA.2014.6860124
24) Strike PW. Statistical Methods in Laboratory Medicine, ISBN:0750613459. 21:525-534.
25) Browne J, O’Hare N. Development of a novel method for assessing balance: the quantitative posturography system. Physiol Meas. 2000; 21:525-534.
26) Bauer C, Gröger I, Rupprecht R, et al. Intrasession reliability o orce platform parameters in community-dwelling older adults. Arcl Phys Med Rehabil. 2008; 89:1977-1982. DOI: https://doi.org/10.1016/j.apmr.2008.02.033
27) Berg K. et al. Clinical and laboratory measures of postural balance in an elderly population. Arch. Phys. Med. Rehabil. 1992; 73:1073-80.
28) Clark RA, Bryant AL, Pua Y, et al. Validity and reliability of the Nintendo Wii Balance Board for assessment of standing balance. Gait Posture. 2010; 31:307-310. DOI: https://doi.org/10.1016/j.gaitpost.2009.11.012
29) Browne J, O'Hare N. Development of a novel method for assessing balance: the quantitative posturography system. Physiological measurement. 2000; 21, 525. DOI: https://doi.org/10.1088/0967-3334/21/4/309
30) Mastantuono T, Lapi D, Battiloro L, et al. A. Microvascular blood flow regulation impairments in hypertensive obese people. 8th Conference of the European Study Group on Cardiovascular Oscillations, ESGCO 2014; art. no. 6847584, pp. 191-192. DOI: https://doi.org/10.1109/ESGCO.2014.6847584
31) Romano M, Faiella G, Clemente F, et al. Analysis of foetal heart rate variability components by means of empirical mode decomposition. IFMBE Proceedings. 2016; 57, pp. 71-74. DOI: https://doi.org/10.1007/978-3-319-32703-7_15
32) Mastantuono T, Muscariello E, Novellino T, et al. Changes in frequency components of blood flow oscillations in hyperglycemic obese people. 8th Conference of the European Study Group on Cardiovascular Oscillations, ESGCO 2014; art. no. 6847581, pp. DOI: https://doi.org/10.1109/ESGCO.2014.6847581
33) Romano M, Iuppariello L, Ponsiglione AM, et al. Frequency and Time Domain Analysis of Foetal Heart Rate Variability with Traditional Indexes: A Critical Survey Computational and Mathematical Methods in Medicine. 2016; art. no. 9585431. DOI: https://doi.org/10.1155/2016/9585431
34) Romano M, Cesarelli M, Iuppariello L, et al. Frequency domain and symbolic dynamics analysis for the study of cardiac pathologies. E-Health and Bioengineering Conference, EHB 2013; art. no. 6707269. DOI: https://doi.org/10.1109/EHB.2013.6707269
35) Romano M, Bifulco P, Iuppariello L, et al. A new tool for foetal phonocardiography simulation. Studies in Health Technology and Informatics, 2015; 210, pp. 743-747. DOI: https://doi.org/10.3233/978-1-61499-512-8-743
36) D' Addio G, Cesarelli M, Bifulco P, et al. Effects of wavelets analysis on power spectral distributions in laser doppler flowmetry time series. IFMBE Proceedings, 2014; 41, pp. 647-650. DOI: https://doi.org/10.1007/978-3-319-00846-2_160
37) Iuppariello L, D'Addio G, Romano M, et al. Analysis of reaching movements of upper arm in robot assisted exercises: Kinematic assessment of Robot assisted upper arm reaching single-joint movements. Giornale Italiano di Medicina del Lavoro ed Ergonomia, 2016; 38(2), 116-127.

How to Cite



Validity and reliability of textile system Sensoria for posturographic measurements: [Validità e affidabilità del sistema tessile Sensoria per le misurazioni post-urografiche]. (2025). Giornale Italiano Di Medicina Del Lavoro Ed Ergonomia, 39(4), 278-284. https://doi.org/10.4081/gimle.644